Kostal PIKO 7.0 Maximize

Kostal PIKO 7.0

Kostal PIKO 7.0

More details

Kostal PIKO 7.0

Supplier
Kostal Solar Electric GmbHRecord-nr.: 6229
ModelPIKO 7.0
        
DC-Part 
Picture
Pnom DC7,3kW
Max PV power7,7kW
Vnom DC680V
MPP range DC from400V
MPP range DC until850V
Vmax DC950V
Min voltage for Pnom400V
Inom DC11,5A
Imax DC12,5A
No of DC connectors2 
No of MPP trackers2 
   
AC-Part
Pnom AC7kW
Pmax AC7kW
Inom AC10,2A
Imax AC10,2A
No of feed-in phases3
Grid freq AC 50HzApprovals
Grid freq AC 60Hz 
Voltage range AC from322V
Voltage range AC until457V
Min Cos-phi0,9 
 Current formsinus 
THD3%
 
Degree of efficiency 
Starts feeding-in at40WRemarks

integrierter Datalogger, integrierter Webserver,i

ntegrierte Wirkleistungssteuerung (Verteilung per Broadcast);

Ereignismeldungen per Mail, Datensicherung,

Datenexport/ Anbindung u.a. zu Meteocontrol-

sowie SolarLog-Portal möglich

Max Standby consumptionW
Max Night consumption1W
Max efficiency97%
European efficiency96,3%
Eff 5% Pnom93,91%
Eff 10% Pnom95,68%
Eff 20% Pnom96,1%
Eff 30% Pnom96,2%
Eff 50% Pnom96,44%
Eff 100% Pnom97 %
  
Design concept                   Data logging
Design conceptTL, HSSData loggingjaOperation weeknein
  VDCjaOperation monthnein
SafetyIDCjaOperation yearnein
Protection typeIP 55PDCjaOperation totalja
Safety classSKL IVACjaE dayja
VDEW-conformIACneinE weekja
Disconnect param adjustablejaFACjaE monthja
ENSjaPACjaE yearja
All pole sensitive RCBjaTEMPjaE totalja
Isolation monitoringjaPmax dayjaDevice statusja
Overload behaviorLBOperation dayneinFaultsja
Internal DC switchja
  DisplayLCD, GD
Mechanical dataStorage capacityca. 1 Jahr
Height450mmKind of data stored15/60 Min-Mittelwert
Width520mmInterface/typeRS485, S0-Impuls I/O, 4xAnalogInput
Depth230mmModemAnschluss DSL-Router, opt. GSM / Analogmodem
Weight33kgEvaluation softwarePIKO Master Control V2
VentilationjaSystem monitoringPIKO Solar Portal
  
Environment                          Other
Noise level46dBAGuarantee5 opt 10, 20years
Ambient temperature from-20°CDelivery timeauf Anfrage
Ambient temperature until60°CTechnical supportHL
Max acceptable temp at Pnom°CReplacement1 Tag
Installation locationinnen, außenConsumer price net
Ambient humidity from0°CConsumer price gross
Ambient humidity until95°CPrice per Watt AC gross
Wholesale price net
ApprovalsENEL DK5940, RD661, EN50438:2007, ÖVE E 8001-4-712, C10/C11, G59/2, TF3.2.1
UL Listing
IEEE 929
CE-sign

   